V5-G/V6-G inverter for Crane
V5-G/V6-G inverter description
1.1 Product Model Description
The digits and letters in the inverter model field on the nameplate indicate such information as the product series, power supply class, power class and software/hardware versions.
1.2 Product Nameplate Description
1.3 Product Series
V6-G-4T□□□G AND V5-G-4T□□□G
Three-phase 400V Constant torque/heavy-duty application
Power (kW) | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | |
Motor power (kW) | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | |
Output | Voltage (V) | Three-phase 0 to rated input voltage | ||||||||||||||
Rated current (A) | 2.5 | 3.8 | 5.5 | 9 | 13 | 17 | 24 | 30 | 39 | 45 | 60 | 75 | 91 | 112 | 150 | |
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||||
Input | Rated voltage/frequency | Three-phase 380V/480V; 50Hz/60Hz | ||||||||||||||
Allowable voltage range | 323V ~ 528V; Voltage unbalancedness ≤3%; allowable frequency fluctuation: ±5% | |||||||||||||||
Rated current (A) | 3.5 | 6.2 | 9.2 | 14.9 | 21.5 | 27.9 | 39 | 50.3 | 60 | 69.3 | 86 | 104 | 124 | 150 | 201 | |
Braking unit | Built-in as standard | Built-in as standard | ||||||||||||||
Protection class | IP20 | |||||||||||||||
Cooling mode | Self-cooling | Forced air convection cooling | ||||||||||||||
Power (kW) | 75 | 90 | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | ||
Motor power (kW) | 75 | 90 | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | ||
Output | Voltage (V) | Three-phase 0 to rated input voltage | ||||||||||||||
Rated current (A) | 176 | 210 | 253 | 304 | 350 | 380 | 426 | 470 | 520 | 600 | 650 | 690 | 775 | 860 | ||
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||||
Input | Rated voltage/frequency | Three-phase 380V/480V; 50Hz/60Hz | ||||||||||||||
Allowable voltage range | 323V ~ 528V; Voltage unbalancedness ≤3%; allowable frequency fluctuation: ±5% | |||||||||||||||
Rated current (A) | 160* | 196* | 232* | 282* | 326* | 352* | 385* | 437* | 491* | 580* | 624* | 670* | 755* | 840* | ||
Braking unit | External braking unit needed | |||||||||||||||
Protection class | IP20 | |||||||||||||||
Cooling mode | Forced air convection cooling |
*V6-G-4T75G and V5-G-4T75G above products are equipped with external DC reactor as standard.
1.4 Product Component Name
1.6 Product Outline, Mounting Dimension, and Weight
voltage | item | product outline, mounting dimension, and weight(mm) | NW (kg) | |||||||
W | H | D | W1 | H1 | D1 | T1 | Install hole d | |||
400V | V6/V5-G-4T0.4G | 118 | 190 | 175 | 105 | 173 | 60.5 | 4 | 5.5 | 2.6 |
V6/V5-G-4T0.75G | ||||||||||
V6/V5-G-4T1.5G | ||||||||||
V6/V5-G-4T2.2G | ||||||||||
V6/V5-G-4T3.7G | 155 | 249 | 185 | 136 | 232 | 69 | 8 | 5.5 | 3 | |
V6/V5-G-4T5.5G | ||||||||||
V6/V5-G-4T7.5G | 210 | 337 | 200 | 150 | 324 | 88 | 2 | 7 | 8.5 | |
V6/V5-G-4T11G | ||||||||||
V6/V5-G-4T15G | 289 | 440 | 220 | 200 | 425 | 88 | 2.5 | 7 | 17 | |
V6/V5-G-4T18.5G | ||||||||||
V6/V5-G-4T22G | ||||||||||
V6/V5-G-4T30G | 319 | 575 | 218 | 220 | 553 | 90.5 | 2.5 | 10 | 25 | |
V6/V5-G-4T37G | ||||||||||
V6/V5-G-4T45G | 404 | 615 | 255 | 270 | 590 | 86.5 | 3.0 | 10 | 35 | |
V6/V5-G-4T55G | ||||||||||
V6/V5-G-4T75G | 465 | 745 | 325 | 343 | 715 | 151.5 | 3.0 | 12 | 55 | |
V6/V5-G-4T90G | ||||||||||
V6/V5-G-4T110G | 540 | 890 | 385 | 370 | 855 | 205.5 | 4.0 | 14 | 85 | |
V6/V5-G-4T132G | ||||||||||
V6/V5-G-4T160G | ||||||||||
V6/V5-G-4T185G | ||||||||||
V6/V5-G-4T200G | 700 | 1010 | 385 | 520 | 977 | 210 | 4.0 | 14 | 125 | |
V6/V5-G-4T220G | ||||||||||
V6/V5-G-4T250G | ||||||||||
V6/V5-G-4T280G | 810 | 1358 | 425 | 520 | 1300 | 210 | 4.0 | 14 | 215 | |
V6/V5-G-4T315G | ||||||||||
V6/V5-G-4T355G | ||||||||||
V6/V5-G-4T400G | ||||||||||
V6/V5-G-4T450G |
1.7 Wiring diagram