• SY16C-Tier 3
  • SY16C-Tier 3
  • SY16C-Tier 3
  • SY16C-Tier 3
  • SY16C-Tier 3
  • SY16C-Tier 3
  • SY16C-Tier 3
  • SY16C-Tier 3

V5-G/V6-G inverter for Crane

V5-G/V6-G high performance inverter used for crane industry

V5-G/V6-G inverter description

1.1 Product Model Description

The digits and letters in the inverter model field on the nameplate indicate such information as the product series, power supply class, power class and software/hardware versions. 

图片1.png

1.2 Product Nameplate Description 

图片2.png

1.3 Product Series

 V6-G-4T□□□G AND V5-G-4T□□□G   

 Three-phase 400V Constant torque/heavy-duty application

Power (kW)

0.4

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

Motor

power (kW)

0.4

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

Output

Voltage (V)

Three-phase 0 to rated input voltage

Rated current (A)

2.5

3.8

5.5

9

13

17

24

30

39

45

60

75

91

112

150

Overload capacity

150%  1 minute, 180%  10 seconds, 200%  0.5 second, interval: 10 minutes (inverse time lag feature)

Input

Rated voltage/frequency

Three-phase 380V/480V; 50Hz/60Hz

Allowable voltage range

323V ~ 528V; Voltage unbalancedness ≤3%; allowable frequency fluctuation: ±5%

Rated current (A)

3.5

6.2

9.2

14.9

21.5

27.9

39

50.3

60

69.3

86

104

124

150

201

Braking unit

Built-in as standard

Built-in as standard

Protection class

IP20

Cooling mode

Self-cooling

Forced air convection cooling

Power (kW)

75

90

110

132

160

185

200

220

250

280

315

355

400

450


Motor

power (kW)

75

90

110

132

160

185

200

220

250

280

315

355

400

450


Output

Voltage (V)

Three-phase 0 to rated input voltage

Rated current (A)

176

210

253

304

350

380

426

470

520

600

650

690

775

860


Overload capacity

150%  1 minute, 180%  10 seconds, 200%  0.5 second, interval: 10 minutes (inverse time lag feature)

Input

Rated voltage/frequency

Three-phase 380V/480V; 50Hz/60Hz

Allowable voltage range

323V ~ 528V; Voltage unbalancedness ≤3%; allowable frequency fluctuation: ±5%

Rated current (A)

160*

196*

232*

282*

326*

352*

385*

437*

491*

580*

624*

670*

755*

840*


Braking unit

External braking unit needed

Protection class

IP20

Cooling mode

Forced air convection cooling

*V6-G-4T75G and V5-G-4T75G above products are equipped with external DC reactor as standard.

1.4 Product Component Name

图片3.png图片4.png

1.6 Product Outline, Mounting Dimension, and Weight

blob.png

voltage

item

product outline, mounting dimension, and weight(mm)

NW

(kg)

W

H

D

W1

H1

D1

T1

Install hole  d

400V

V6/V5-G-4T0.4G

118

190

175

105

173

60.5

4

5.5

2.6

V6/V5-G-4T0.75G

V6/V5-G-4T1.5G

V6/V5-G-4T2.2G

V6/V5-G-4T3.7G

155

249

185

136

232

69

8

5.5

3

V6/V5-G-4T5.5G

V6/V5-G-4T7.5G

210

337

200

150

324

88

2

7

8.5

V6/V5-G-4T11G

V6/V5-G-4T15G

289

440

220

200

425

88

2.5

7

17

V6/V5-G-4T18.5G

V6/V5-G-4T22G

V6/V5-G-4T30G

319

575

218

220

553

90.5

2.5

10

25

V6/V5-G-4T37G

V6/V5-G-4T45G

404

615

255

270

590

86.5

3.0

10

35

V6/V5-G-4T55G

V6/V5-G-4T75G

465

745

325

343

715

151.5

3.0

12

55

V6/V5-G-4T90G

V6/V5-G-4T110G

540

890

385

370

855

205.5

4.0

14

85

V6/V5-G-4T132G

V6/V5-G-4T160G

V6/V5-G-4T185G

V6/V5-G-4T200G

700

1010

385

520

977

210

4.0

14

125

V6/V5-G-4T220G

V6/V5-G-4T250G

V6/V5-G-4T280G

810

1358

425

520

1300

210

4.0

14

215

V6/V5-G-4T315G

V6/V5-G-4T355G

V6/V5-G-4T400G

V6/V5-G-4T450G

1.7 Wiring diagram

图片9.png