1.1 Product Model Description

The digits and letters in the inverter model field on the nameplate indicate such information as the

product series, power supply class, power class and software/hardware versions.

blob.png

1.2 Product Nameplate Description

blob.png

1.3 Product Series

V6−H−4T□□□G Three−phase 400V Constant torque/heavy−duty application

Power (kW)0.751.52.23.75.57.5111518.5223037455575

Motor

power (kW)

0.751.52.23.75.57.5111518.5223037455575
OutputVoltage (V)Three−phase 0 to rated input voltage
Rated current (A)2.53.85.59131724303945607591112150

Overload

capacity

150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag

feature)

Input

Rated

voltage/frequenc

y

Three−phase 380V/480V; 50Hz/60Hz

Allowable voltage

range

323V ~ 528V; Voltage unbalancedness ≤3%; allowable frequency fluctuation: ±5%
Rated current (A)2.84.26.1101519263343506683100123165
Braking unitBuilt−in as standardBuilt−in as option
Protection class                                                         IP20
Cooling modeSelf−coolingForced air convection cooling
Power (kW)90110132160185200220250280315355400450500

Motor

power (kW)

90110132160185200220250280315355400450500
OutputVoltage (V)Three−phase 0 to rated input voltage
Rated current (A)176210253304350380426470520600650690775860

Overload

capacity

150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag

feature)

InputRated

voltage/frequenc

y

Three−phase 380V/480V; 50Hz/60Hz

Allowable voltage

range

323V ~ 528V; Voltage unbalancedness ≤3%; allowable frequency fluctuation: ±5%
Rated current (A)160*196*232*282*326*352*385*437*491*580*624*670*755*840*
Braking unitExternal braking unit needed
Protection classIP20
Cooling modeForced air convection cooling

*V6−H−4T90G and above products are equipped with external DC reactor as standard.

1.4 Technical Specifications of Product









Control

features

Control modeVector control 1

Vector control 2

(Without encoder)

Vector control 2

(With encoder )

Startup torque0.50Hz 180%0.25Hz 180%0.00Hz 180%
Speed adjustment range1:1001:2001:1000
Speed stabilization

precision

± 0.5%± 0.2%± 0.02%
Torque controlNYY
Torque precision±5%±5%
Torque response time<20ms<10ms











Product

functions

Key functions

Undervoltage adjustment, switching of AC operation grounding, protective

grounding and DC operation grounding, rotation speed tracing, torque

limitation, multi−speed operation (up to 23 speeds), auto tuning, S curve

acceleration/deceleration, slip compensation, PID adjustment, drooping

control, current limiting control, torque control mode and speed control mode

switching, manual/auto torque boost. current limiting, multi−functional

input/output terminal

Frequency setting mode

Operation panel setting, terminal UP/DN setting, host computer

communication setting, analog setting AI1/AI2/AI3, terminal pulse DI setting

Frequency range

0.00 ~ 300.00Hz Note: Upon the control mode of vector control 1 0.0 ~

3000.0Hz, which can be customized according to the customer demand

Startup frequency0.00~60.00Hz
Acceleration/deceleration

time

0.1~36000s

Powered braking

capacity

Braking unit action voltage: 650 ~ 750V; operating time: 100.0s; The

braking unit can be embedded for V6−H−4T75G and below equipment

DC braking capacityDC braking initial frequency: 0.00 ~ 300.00Hz; DC braking current: Constant

torque: 0.0 ~ 120.0%, Variable torque: 0. 0 ~ 90.0%

DC braking time: 0.0 ~ 30.0s; there is no initial waiting time for the DC braking

to realize quick braking

Magnetic flux braking

function

Ongoing action and no action upon deceleration as option, no action upon

deceleration at default








Unique

functions

Multifunctional M keyThe unique multifunctional key is used to set the frequently used operations:

JOG, emergency shutdown, running command reference mode switch ,

menu switching

Multiple menu modes

Basic menu mode, fast menu mode. Menu mode of non−leave−factory value

function codes, Menu mode of last changed 10 function codes

Parameter copy

The standard operation panel can realize the parameter upload, download

and display the copy progress. The user can select to forbid the overwriting of

the uploaded parameters.

Displayed/hidden

function code

The customer can select to display or hide the function codes by themselves.

Dual 485 communication

ports

Dual 485 communication ports support Modbus protocol (RTU). The standard

operation panel can realize remote control box function with a maximum

distance of 500m.

Operation panel

Button type or shuttle type operation panel optional, protection class: IP20 as

standard, IP54 as option

Common DC busThe full series can realize common DC bus supply for several inverters.
Independent duct

The full series adopts independent duct design and supports the installation

of heatsink outside the cabinet

Universal expansion

interface

Universal expansion board equipped with CPU for supporting customers

secondary development: physical interface SPI bus, software protocol

Modbus

Expansion card

User’s secondary development card, injection molding machine interface

card, PG feedback card, air compressor control card, communication adapter

card, power monitoring card, phase sequence detection card, external power

rectifying card

Power−up

auto−detection

Realizing the power−up auto−detection of internal and peripheral circuits,

including motor grounding, abnormal +10V power supply output, abnormal

analog input, and disconnection

Protection

function

Power supply undervoltage, overcurrent protection, overvoltage protection, interference protection,

abnormal comparison reference input, auto−tuning failure, module protection, heatsink overtemperature

protection, inverter overload protection, motor overload protection, peripheral protection, abnormal current

detection, output to ground short circuit, abnormal power failure during operation, abnormal input power,

output phase failure, abnormal EEPROM, abnormal relay contact, temperature sampling disconnection,

encoder disconnection, abnormal +10V power supply output, abnormal analog input, motor

overtemperature (PTC), abnormal communication, abnormal version compatibility, abnormal copying,

abnormal expansion card connection, terminal mutual exclusion detection failure, hardware overload

protection

Efficiency

At rated power, 7.5kW and below power class ≥93%, 45kW and below power class ≥95%, 55kW and

above power class ≥98%








Environment

Operating site

The product shall be mounted vertically in the electric control cabinet with

good ventilation. Horizontal or other installation modes are not allowed. The

cooling media is the air. The product shall be installed in the environment free

from direct sunlight, dust, corrosive gas, combustible gas, oil mist, steam and

drip.

Ambient temperature

−10 ~ +40ºC, derated at 40 ~ 50ºC, the rated output current shall be

decreased by 1% for every temperature rise of 1ºC

Humidity5 ~ 95%, no condensing
Altitude

0 ~ 2000m, derated above 1000m, the rated output current shall be

decreased by 1% for every rise of 100m

Vibration3.5mm,2~9Hz; 10 m/s2,9~200Hz; 15 m/s2,200~500Hz
Storage temperature−40~+70ºC


1.5 Product Component Name

blob.png

V6−H−2T0.4G~V6−H−2T2.2G

V6−H−4T7.5G/11L and below power class                                                               V6−H−4T11G/15L and above power class

1.6 Product Outline, Mounting Dimension, and Weight

blob.png

Product outline and mounting dimension