Features:
1, Reduced commissioning and servicing time due to easily and removable keypad
2, High performance and comprehensive protection function
3, Standard built-in RS485 for communication
4, Over 10 years market and application experience ensure the stability and performance.
Application: grinding machine, blowing machines, washing machines, conveyor belt; fan of drying machine, etc
AC Drive from 45kw to 160kw/380v(300-500V ac)
AC Drive model | Adapted motor | Rated input current(A) | Shape case | |
KW | HP | |||
VT2-4T-045 | 45 | 60 | 90 | F5 |
VT2-4T-055 | 55 | 70 | 110 | F5 |
VT2-4T-075 | 75 | 100 | 150 | F6 |
VT2-4T-090 | 93 | 125 | 170 | F6 |
VT2-4T-110 | 110 | 150 | 210 | F7 |
VT2-4T-132 | 132 | 175 | 250 | F7 |
VT2-4T-160 | 160 | 210 | 300 | F7 |
Item | Specifications | ||
Basic function | Control system | High performance of current vector control technology to realize 3 phase asynchronous motor control | |
Drive performance | High efficiency driving for induction motor and synchronous motor | ||
Maximum frequency | Vector control:0~500Hz V/F control:0~500Hz | ||
Carrier frequency | 0.5kHz~16kHz; the carrier frequency will be automatically adjusted according to the load characteristics | ||
Input frequency resolution | Digital setting: 0.01Hz Analog setting: maximum frequency ×0.025% | ||
Control mode | Open loop vector control(SVC) V/F control | ||
Startup torque | G type:0.5Hz/150%(SVC);0Hz/180%(FVC) P type:0.5Hz/100% | ||
Speed range | 1:100(SVC) | 1:1000(FVC) | |
Speed stabilizing precision | ±0.5%(SVC) | ±0.02%(FVC) | |
Torque control precision | ±5%(FVC) | ||
Over load capability | G type:150% rated current 60 seconds; 180% rated current 3 seconds; P type:120% rated current 60 seconds; 150% rated current 3 seconds | ||
Torque boost | Auto torque boost function;Manual torque boost 0.1%~30.0% | ||
V/F curve | Linear V/F, multi-point V/F and square V/F curve (power of 1.2, 1.4, 1.6, 1.8, 2) | ||
V/F separation | In 2 ways:separation ,semi separation | ||
Acc. / dec curve | Straight line or S curve acceleration and deceleration mode. Four kinds of acceleration and deceleration time. Acceleration and deceleration time range between 0.0s to 6500s. | ||
DC brake | DC brake frequency: 0.00Hz to maximum frequency. Brake time: 0.0s to 36.0s, and brake current value: 0.0% to 100.0%. | ||
Jog control | Jog frequency range: 0.00Hz~50.00Hz. Jog acceleration/deceleration time 0.0s~6500.0s. | ||
Simple PLC and Multi-speed running | It can realize at maximum of 16 segments speed running via the built-in PLC or control terminal. | ||
Built-in PID | It is easy to realize process-controlled closed loop control system | ||
Auto voltage regulation (AVR) | It can keep constant output voltage automatically in the case of change of network voltage. | ||
Over-voltage/current stall control | It can limit the running voltage/current automatically and prevent frequent over-voltage/current tripping during the running process | ||
Quick current limit | Minimize the over-current fault, protect normal operation of the AC Drive | ||
Torque limit & control | "Excavators" characteristics, automatically limit torque during operation, prevent frequent over-current tripping. Closed loop vector mode can realize the torque control. | ||
Personalized | Instantaneous stop non-stop | When instantaneous power off, voltage reduction is compensated through load feedback energy, which could make AC Drive keep running in a short period of time. | |
Rapid current limit | To avoid AC Drive frequently over-current fault. | ||
Timing control | Timing control function:set time range 0Min~6500.0Min | ||
Running command channel | Three types of channels: operation panel reference, control terminal reference and serial communication port reference. These channels can be switched in various modes. | ||
Frequency source | There are totally eleven types of frequency sources, such as digital reference, analog voltage reference , analog current reference, pulse reference , MS speed, PLC, PID and serial port reference. | ||
Input terminal | Standard: 5 Digital input terminals, DI5 can be used as 100kHz high-speed input pulse. 2 Analog input terminals 1 Support 0-10V voltage input or 0~20mA current input. | ||
Output terminal | Standard: 1 Digital output terminals, 1 Relay output terminal; 2 Analog output terminals, support 0~20mA output current or 0~10V output voltage; Extended function: 1 Digital output terminal; 1 Relay output terminal ; 1 Analog output terminal, support 0~10V output voltage. | ||
Keyboard potentiometer | Equipped with keyboard potentiometer or coding potentiometer | ||
Display | Protection function | It can implement power-on motor short-circuit detection, input / output phase loss protection, over current protection, over voltage protection, under voltage protection, overheating protection and overload protection. | |
Using place | Indoor, and be free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt. | ||
Environment | Altitude | Below 1000m | |
Ambient temperature | -10 ℃ to +40 ℃ (Derating use when under ambient temperature of 40 ℃ to 50 ℃) | ||
Humidity | Less than 95%RH, without condensing | ||
Vibration | Less than 5.9m/s2 (0.6g) | ||
Storage temperature | -10℃~+50℃ |
Outer Shapes
Size 380v-VT2 Series
AC Drive model | 45kw-160kw 380V Three Phase Input & Three Phase Output | ||||||||
H (mm) | W (mm) | D (mm) | H1 (mm) | W1 (mm) | R1 (mm) | N.W. (kg) | G.W. (kg) | Case | |
45kw-380v 55kw-380v | 600.1 | 385.4 | 267 | 580 | 260 | Ø9 | 27 | 39 | F5 |
75kw-380v 93kw-380v | 700 | 473 | 311 | 678 | 343 | Ø10 | 43 | 58 | F6 |
110kw-380v 132kw-380v 160kw-380v | 849 | 480 | 389 | 822.1 | 369 | Ø10 | 85 | 98 | F7 |