• SY16C-Tier 3
  • SY16C-Tier 3
  • SY16C-Tier 3
  • SY16C-Tier 3

VT2 High Performance 380V Frequency Converter

VT2 High Performance 380V Drive from 0.75KW to 2.2KW

VTdrive VT2 380V inverters are high performance open loop vector inverters for controlling asynchronous AC induction motors.It features versatile driving controls, modular design, wide variety of applications, easy maintenance, low malfunction rate,etc.Widely used in various applications and well received by lots of clients worldwide.



Features:


1, Power Range 0.4Kw up to 500Kw

2, Removable LED keypad to copy parameters

3, High performance vector control technology

4,Compatible with any IEC three-phase asynchronous motors



Applications: Air Compressor, Sugar Mill, Mechanicals, textile machinery, packaging machinery, rubber machinery, printing machinery, construction machinery, motor machine, building materials, mining, water industry


Item

Specifications

Basic function

Control system

High performance of current vector control technology to realize 3 phase  

asynchronous motor control

Drive performance

High efficiency driving for induction motor and synchronous motor

Maximum frequency

Vector control0~500Hz      V/F control0~500Hz

Carrier frequency

0.5kHz~16kHz; the carrier frequency will be automatically adjusted according to the load characteristics

Input frequency resolution

Digital setting0.01Hz

Analog settingmaximum frequency ×0.025%

Control mode

Open loop vector control(SVC)

V/F control

Startup torque

G type0.5Hz/150%(SVC)0Hz/180%(FVC)  P type0.5Hz/100%

Speed range

1100(SVC)

11000(FVC)

Speed stabilizing precision

±0.5%(SVC)

±0.02%(FVC)

Torque control precision

±5%(FVC)

Over load capability

G type150% rated current 60 seconds; 180% rated current 3 seconds;

P type120% rated current 60 seconds; 150% rated current 3 seconds

Torque boost

Auto torque boost functionManual torque boost 0.1%~30.0%

V/F curve

Linear V/F, multi-point V/F and square V/F curve (power of 1.2, 1.4, 1.6, 1.8, 2)

V/F separation

In 2 waysseparation ,semi separation

Acc. / dec curve

Straight line or S curve acceleration and deceleration mode.

Four kinds of acceleration and deceleration time. Acceleration and deceleration time range between 0.0s to 6500s.

DC brake

DC brake frequency0.00Hz to maximum frequency. Brake time0.0s to 36.0s, and brake current value0.0% to 100.0%.

Jog control

Jog frequency range0.00Hz~50.00Hz. Jog acceleration/deceleration time 0.0s~6500.0s.

Simple PLC and Multi-speed running

It can realize at maximum of 16 segments speed running via the built-in PLC or control terminal.

Built-in PID

It is easy to realize process-controlled closed loop control system

Auto voltage regulation (AVR)

It can keep constant output voltage automatically in the case of change of network voltage.

Over-voltage/current stall control

It can limit the running voltage/current automatically and prevent frequent over-voltage/current tripping during the running process

Quick current limit

Minimize the over-current fault, protect normal operation of the AC Drive  

Torque limit & control

"Excavators" characteristics, automatically limit torque during operation, prevent frequent over-current tripping.

Closed loop vector mode can realize the torque control.

Personalized

Instantaneous stop

non-stop

When instantaneous power off, voltage reduction is compensated through load feedback energy, which could make AC Drive keep running in a short period of time.

Rapid current limit

To avoid AC Drive frequently over-current fault.

Timing control

Timing control functionset time range 0Min~6500.0Min

Running command channel

Three types of channelsoperation panel reference, control terminal reference and serial communication port reference. These channels can be switched in various modes.

Frequency source

There are totally eleven types of frequency sources, such as digital reference, analog voltage reference , analog current reference, pulse reference , MS speed, PLC, PID and serial port reference.

Input terminal

Standard:

5 Digital input terminals, DI5 can be used as 100kHz high-speed input pulse.

2 Analog input terminals

1 Support 0-10V voltage input or 0~20mA current input.

Output terminal

Standard:

1 Digital output terminals,

1 Relay output terminal;

2 Analog output terminals, support 0~20mA output current or 0~10V output voltage;

Extended function:

1 Digital output terminal;

1 Relay output terminal ;

1 Analog output terminal, support 0~10V output voltage.

Keyboard potentiometer

Equipped with keyboard potentiometer or coding potentiometer

Display

Protection function

It can implement power-on motor short-circuit detection, input / output phase loss protection, over current protection, over voltage protection, under voltage protection, overheating protection and overload protection.

Using place

Indoor, and be free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.

Environment

Altitude

Below 1000m

Ambient temperature

-10 to +40 (Derating use when under ambient temperature of 40 to 50 )

Humidity

Less than 95%RH, without condensing

Vibration

Less than 5.9m/s2 (0.6g)

Storage temperature

-10℃~+50℃



Outer Shapes

image.png

Products Specifications

AC Drive  model

0.75kw-2.2kw 380V Three Phase Input & Three Phase Output


W (mm)

W1

(mm)

L3

(mm)

L2

(mm)

H

(mm)

H1

(mm)

Hole

(mm)

N.W.

(kg)

G.W.

(kg)

Case

0.75kw-380v

1.5kw-380v

2.2kw-380v

100

92

152

143

116.5

127

Ø2

1

1.5

F1

AC Drive  models

 4kw-7.5kw 380V Three Phase Input & Three Phase Output


W

(mm)

W1

(mm)

H

(mm)

H1

(mm)

D

(mm)

D1

(mm)

N.W.

(kg)

G.W.

(kg)

Case

4kw-380v

5.5kw-380v

7.5kw-380v

130

115

264

244

153

9

2.9

3.5

F2